Dry heat sterilizer for manicure tools CH-360 T
Dry heat sterilizer for manicure tools CH-360 T
A sterilizer-dryer is an ideal option for sterilizing manicure and pedicure tools. The main advantage of the device is efficiency and quick results. Completely kills all pathological microflora, makes tools suitable for work. Provides comfort and safety during favorite procedures, improving their quality.
The side handles are made of durable plastic.
Features of the sterilizer-dryer for tools
● It is made of stainless steel, which does not succumb to the negative effects of external factors and ensures the durability of the device.
● Withstands large loads during operation.
● It has a built-in timer, working indicator and sound notification, which make working with the device easy.
● There is a regulator for choosing the temperature mode.
● In addition to excellent technical characteristics, the equipment has a pleasant design and small dimensions.
● It is characterized by effective work with minimal resource consumption.
● The product is original, so its flawless functioning is guaranteed.
The Beleon online store offers a high-quality sterilizer-dryer for manicure tools at an affordable price. Delivery is carried out throughout the country.
Experience all the advantages of working with a high-quality and effective dry-heat cabinet for manicure and pedicure tools firsthand! We present to you a unique model of a dry heat sterilizer for manicure tools, which will provide you with high-quality disinfection and a quick result.
Features of the dry heat sterilizer of manicure tools
-
The presented model of the dry heat sterilizer for manicure tools is characterized by excellent build quality, it is made of proven stainless steel.
-
The tool is equipped with a special timer, a work indicator and a sound notification function.
-
Also, the dry heat sterilizer for pedicure tools is equipped with a thermostat, which you can set the desired temperature (from 0 to 220 degrees).
Advantages of a dry heat sterilizer for tools
ORIGINAL! Dry heat sterilizer for tools has a long service life. The advantages of this drying oven are not only in price, but also in size, it is very compact.
Another indisputable advantage of the presented dry heat sterilizer for manicure and pedicure tools is its durability and resistance to wear. It is impossible not to pay attention to the compactness and pleasant design of the equipment, it will surely decorate your desktop.
Instructions for use
PRECAUTIONS
ATTENTION!!!
The recommended temperature is no more than 175-180 °C for 15 minutes. Next, look at the indicator in the craft package. If the time is greatly exceeded, the tools may become dull!
PREPARATION FOR USE
1. Open the cover and check the metal pallet for the possible presence of the remains of the protective rubber film on all corners from above and below. If you find it, feel free to peel it off, so that when you start it for the first time, you will not have a strong smell from it.
2. Do the same with the metal bottom
3. Do a test run without tools for 15 minutes at 150°C. (How to start - below)
INCLUSION AND USE
1. Connect the power cord to the sterilizer and the socket (Euro standard socket).
2. Place the instrument to be sterilized in a stainless steel bath and close the lid of the sterilizer.
3. Set the required time. Start with the working temperature in a dry heat of 175-180°C for 15 minutes! At this temperature, 100% of microbes and bacteria are killed.
4. Set the required temperature (the sterilizer will turn on).
5. The red indicator shows that the sterilizer has started working.
6. The green indicator shows that the sterilizer has started heating (as soon as it goes out, it means that the sterilizer has reached the required temperature).
7. The red indicator has gone out - the sterilizer has completed its work.
8. Carefully open the lid of the sterilizer and with the help of two rings (supplied), hook the tray by the special lugs and remove it to the previously prepared surface.
9. Wait for the tool to cool completely.
10. Use the CH-360T drying cabinet only according to our instructions!
CLEANING
· Carry out periodic cleaning of the equipment.
· Before cleaning, make sure that the device is disconnected from the network (the plug is removed from the outlet) and it has completely cooled down.
· Do not turn on the device immediately after cleaning.
· Only cleaning of the case, lid and inner surface of the container is allowed.
· If liquids or substances get inside the device, do not try to remove them yourself, contact the technical support center and do not use the device until the malfunction is eliminated.
When cleaning the device, do not use solvents, flammable and alcohol-containing liquids, cleaning powders that can scratch the surface of the case or the inner surface of the device.
· Use only mild detergents dissolved in water. As a material, use a damp, soft cloth that does not leave fibers when cleaning (do not use cotton wool or similar cotton swabs).
· At the end of the cleaning procedure, wipe the surfaces with a dry cloth to remove the remaining moisture. Make sure that there are no traces of detergent left on the panels of the device.
· Before any movement of the device, make sure that it is disconnected from the network.
· To avoid the risk of getting a burn, do not touch the lid of the device and the tray during sterilization and immediately after the end of processing the instrument.
· During the processing of the tool, the cover of the device must remain closed.
· Do not cover the device with a towel or other fabrics that can block air recirculation through specially provided slots.
· Do not use plastic or wooden tools in the device. The device is intended for processing only metal tools that can withstand the temperature set by you.
· Disconnect the device from the network at the end of the working day or after the end of operation.